Solutions for Corrosion Under Insulation

Acuren offers a fully integrated and comprehensive approach to detecting and solving corrosion under insulation challenges backed by engineers and corrosion specialists with years of experience.

What is Corrosion Under Insulation (CUI)?

CUI (Corrosion Under Insulation) is external degradation on a component as a result of water trapped under insulation or fireproofing. CUI can affect carbon steels, low alloy steels, 300 series stainless steels, and even duplex stainless steels. CUI typically affects equipment that operates continuously or intermittently between:

  • Carbon & low alloy steels: -12°C (10°F) to 175°C (350°F)
  • Austenitic and duplex stainless steels: 60°C (140°F) to 205°C (400°F)

Corrosion Under Insulation (CUI) is a damage mechanism that affects all industrial facilities. Failure of in-service equipment can be catastrophic and extremely costly. Current industry practices for detection and mitigation are inefficient and expensive. Acuren is thinking outside the box, pioneering alternative strategies for tackling this common but costly problem.

Acuren leads the industry as the one true supplier that can be the single turnkey vendor to execute comprehensive CUI programs.

 

Engineering Solutions and Programs

Acuren alternative strategies callout tag

  • CUI program development
  • Corrosion engineering, materials selection, mitigation solutions
  • Manual development on inspection & mitigation of CUI
  • Perform engineering threat assessments
  • Experienced in-house corrosion engineering capabilities
  • Equipment condition assessment – RSTRENG / APCAT Calculations
  • Fitness for service assessments (e.g. API 579)
  • Repair plan development
  • Create and implement Risk Based Inspection (RBI) programs
  • Finite Elemental Analysis (FEA)

Visual Inspection

  • Experienced visual inspectors perform external inspections of equipment:
    • RBI (API 580/API 581)
    • Piping (API 570)
    • Pressure Vessels (API 510)
    • Boilers (NBIC, ABSA)
    • Structural
    • Other
  • Asset integrity management
  • Assess for CUI potential
  • Selection of suitable NDE method(s)
  • Circuitize piping, select condition monitoring locations (CML’s)

All Inspection, NDE & Industrial Services Can Be Provided From Ropes

WHY ACUREN?
A fully integrated approach, combining engineering, inspection, NDE, industrial trades and rope access services. Acuren leads the industry as the one true supplier that can be the single turnkey vendor to execute comprehensive CUI programs. Acuren innovation, advanced applications, and cutting-edge inspection solutions result in significant cost savings, reducing unnecessary mechanical scopes (insulation stripping only where required), saving precious time and reducing material waste while limiting exposure to potential hazards. Leading provider of robust CUI programs, founded in sound engineering practice through unparalleled industry knowledge, leveraging decades of experience. Rigorous training and competency programs for personnel. Diagnose the root cause, not the symptoms. Design the right program and tools for the application.

 

Acuren NDE Methods for CUI Inspection

  • Moisture Detection Imaging (MDI) – Neutron Backscatter
    Pulsed Eddy Current (PEC)
  • Radiography
    • Real Time Radiography (RTR)
    • Computed Radiography (CR)
    • Digital Radiography (DR)
  • Guided Wave Ultrasonic (GUL)
  • Infrared Thermography (IR)
    Laser Scanning
  • Advanced Ultrasonic
    Inspection
    • PAUT
    • TOFD
    • AUT
  • Ultrasonic Thickness (UT)
    Measurements

Rope Access and Industrial Solutions

Rope Access Methods:

  • Where scaffold or other means of access are not practical, Acuren can utilize rope access means to assess CUI (e.g. modular piping, towers, stacks).
  • All inspection, NDE and industrial services can be provided from ropes.

Industrial Services:

  • Journeyman Insulators
    • Insulation removal/repairs
    • Insulation installation
    • Asbestosabatement
    • CML ports installed
    • Fireproofing
  • Repairs/Replacement
    • Welding and fabrication
    • Pipefitting
  • Pressure cleaning and blasting
  • Coatings – NACE Inspectors, coat
    ing removal and recoating
  • Electrical and instrumentation

 

To speak to our team of CUI specialists, please call 888-534-4162 or email cui@acuren.com.

 

Connect With Acuren For Expert Solutions For CUI

Our experts have years of experience detecting and solving corrosion under insulation challenges across a range of industries. Our capabilities make us the industry-leading turnkey vendor for the execution of comprehensive CUI programs. Request our services online to begin the process, or call us at 888-534-4162. For general questions, reach out to our CUI specialists at cui@acuren.com.

Share the Post:

Related Posts

Advance Coating Solutions - featured image

Strategic Acquisition of Advance Coating Solutions Inc.

Join our Newsletter

Subscribe Now Arrow Icon
The owner of this website has made a commitment to accessibility and inclusion, please report any problems that you encounter using the contact form on this website. This site uses the WP ADA Compliance Check plugin to enhance accessibility. Skip to content